Summary for Test 2026-03-16-69-2
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 1000851 DEA: 07351704 EFIS: 0718000204 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-118,118-15.6/R17.9 |
| Award Date | 03/25/2025 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PAVEMENT AND PLACE RUBBERIZED HMA. |
| Location Description | VENTURA COUNTY IN MOORPARK AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 03/11/2025) |
Sample Information
| Sample Taken Date | 03/16/2026 | Sample Unique Key | 69 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/23/2026 |
| Sample type | Verification | A brief description of the sample | Asphalt Binder Sample |
| The quantity of what the sample constitutes | 1can | From where was the sample collected | Source |
| First name of sampler or witnessed by | John/ Cristian/ Baher | Last name of sampler or witnessed by | John |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan-Sun Valley | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-16 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2026-03-16-69
DIME Test ID: 2026-03-16-69-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2026-04-07
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Sunday Agude
Date of test: 03/27/2026
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 203.221 grams
Mass of container #2 before test (m2i): 206.861 grams
Mass of container #1 after test (m1f): 203.032 grams
Mass of container #2 after test (m2f): 206.668 grams
Mass of empty container #1: 168.202 grams
Mass of empty container #2: 171.916 grams
Mass correction factor: 0.006
Average mass change: -0.540 percent
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/7/2026 ✔