Summary for Test 2026-03-14-21-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1001440
DEA: 07370804
EFIS: 0720000139
DIST-CO-RTE-PM07-LA-5-30.6/31.6
Award DateNot set
Closeout DateNot set
Work DescriptionREMOVE CONCRETE PAVEMENT AND BASE, AND PLACE JPCP.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM 0.2 MILE NORTH OF SAN FERNANDO BOULEVARD TO 0.2 MILE SOUTH OF COHASSET STREET
QA Service Level1 (Verified on 08/15/2025)

Sample Information

Sample Taken Date03/14/2026 Sample Unique Key21
Date that the sample was received by the laboratory/organization performing the testing03/14/2026 Sample typeQuality Assurance
A brief description of the sampleLCB-RSC The quantity of what the sample constitutes40 CY of 600 CY
From where was the sample collectedJob Site First name of sampler or witnessed byEdmond
Last name of sampler or witnessed byJabbour Title of samplerField Technician
Telephone number of sampler909-239-8226 Laboratory sample identification26-0946
Linked DIME Sample ID The fabricator/manufacturer/facility nameNational Ready Mix - Sun Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberS67C741L0
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected320397
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedTruck Chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-03-14-21
DIME Test ID: 2026-03-14-21-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-03-25

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jeffrey Diaz
Date of test: 03/21/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.10 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 214081 lb
Maximum load on cylinder 2: 213430 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 29.22 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength (to nearest 10 psi): 7420 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/25/2026 ✔