Summary for Test 2026-03-16-9-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1001329 DEA: 100X7404 EFIS: 1013000008 |
|---|---|
| DIST-CO-RTE-PM | 10-CAL-12-17.1/17.5 |
| Award Date | 09/03/2025 |
| Closeout Date | Not set |
| Work Description | BRIDGE REPLACEMENT. |
| Location Description | CALAVERAS COUNTY NEAR SAN ANDREAS FROM 0.2 MILE WEST OF NORTH FORK CALAVERAS RIVER BRIDGE TO 0.2 MILE EAST OF NORTH CALAVERAS RIVER BRIDGE |
| QA Service Level | 1 (Verified on 06/16/2025) |
Sample Information
| Sample Taken Date | 03/16/2026 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/19/2026 |
| Sample type | Quality Assurance | A brief description of the sample | Flash Welded Hoops |
| The quantity of what the sample constitutes | 2 Lots of 491 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
| Title of sampler | QA | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CMC Rebar San Bernadino | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-027-26 | Structure unique identifier | |
| Structure name | Bid Item | 3936405 |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 9010749 |
| Hoop Manufacturer Lot Number(s) | Lots #1 and #4 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #7 |
| Diameter of Hoop | 3'-8" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Arizona |
| Welding Company | CMC Rebar San Bernardino | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-03-16-9
DIME Test ID: 2026-03-16-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-03-25
Test Results
Number of Samples: 8
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 03/25/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 7 | 0.60 | 56720 | 94500 | ok necking | Kleinfelder |
| 2 | 2 | 1 | 7 | 0.60 | 57520 | 96000 | ok necking | Kleinfelder |
| 3 | 3 | 1 | 7 | 0.60 | 57000 | 95000 | ok necking | Kleinfelder |
| 4 | 4 | 1 | 7 | 0.60 | 56020 | 93500 | ok necking | Kleinfelder |
| 5 | 1 | 4 | 7 | 0.60 | 54960 | 91500 | ok necking | Kleinfelder |
| 6 | 2 | 4 | 7 | 0.60 | 57340 | 95500 | ok necking | Kleinfelder |
| 7 | 3 | 4 | 7 | 0.60 | 54550 | 91000 | ok necking | Kleinfelder |
| 8 | 4 | 4 | 7 | 0.60 | 55310 | 92000 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/25/2026 ✔