Summary for Test 2026-03-16-12-1
Test performed: ASTM A970-18Project Information
| Project Identifiers | Project ID: 1001375 DEA: 040A53T4 EFIS: 0421000155 COOP: 040A53TCM |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-L1.8/L3.2 |
| Award Date | 06/20/2025 |
| Closeout Date | Not set |
| Work Description | Construct I-80 WB Truck Scales |
| Location Description | CONSTRUCTION ON STATE HIGHWAY IN SOLANO COUNTY IN AND NEAR FAIRFIELD ON ROUTE 12 FROM THE 80/12 EAST JUNCTION TO 0.9 MILE EAST OF CHADBOURNE ROAD UNDERCROSSING AND ON ROUTE 80 FROM 0.5 MILE WEST OF DAN WILSON CREEK BRIDGE TO WEST TEXAS STREET UNDERCROSSI |
| QA Service Level | 1 (Verified on 07/10/2025) |
Sample Information
| Sample Taken Date | 03/16/2026 | Sample Unique Key | 12 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/19/2026 |
| Sample type | Quality Assurance | A brief description of the sample | #9 HRC 150 T Heads |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Alexis | Last name of sampler or witnessed by | Millan |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 9097569960 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | HRC | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L191-039-26 | Structure unique identifier | |
| Structure name | Bid Item | 3928521 |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 4153326 | Head Manufacturer Lot Number(s) | C258174 |
| Rebar Size | #9 | Headed Bar Model Name | HRC Type 150 |
| Size of Head | Reduced Size - 4x | Head Connection Type | |
| Head Shape | Circular | Rebar Manufacturer | CMC Steel Arizona |
| Head Manufacturer | HRC Fountain Valley | Head Fabricator | Nucor Utah |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | 9FW-17-04 |
Test Details
DIME Sample ID: 2026-03-16-12
DIME Test ID: 2026-03-16-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2026-03-25
Test Results
Number of Headed Bar Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 03/25/2026
UTM: NA
Temperature: 0 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 90390 | 90500 | Ok Necking | Kleinfelder |
| 2 | 1 | 1 | 88860 | 89000 | Ok Necking | Kleinfelder |
| 3 | 1 | 1 | 89620 | 89500 | Ok Necking | Kleinfelder |
| 4 | 1 | 1 | 89640 | 89500 | Ok Necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/25/2026 ✔