Summary for Test 2025-09-20-57-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 993454
DEA: 040K8004
EFIS: 0416000141
COOP: 042892
DIST-CO-RTE-PM04-MRN-101-13.7
Award Date02/05/2025
Closeout DateNot set
Work DescriptionCONSTRUCT ROUNDABOUT, CURB RAMPS AND SW, SIGNAL AND LIGHTING SYSTEMS.
Location DescriptionMARIN COUNTY IN SAN RAFAEL AT FREITAS PARKWAY OVERCROSSING
QA Service Level1 (Verified on 12/10/2021)

Sample Information

Sample Taken Date09/20/2025 Sample Unique Key57
Date that the sample was received by the laboratory/organization performing the testing09/23/2025 Sample typeQuality Assurance
A brief description of the sample3/4 HMA with 15% RAP The quantity of what the sample constitutes750 tons
From where was the sample collectedJob Site First name of sampler or witnessed byIganacio
Last name of sampler or witnessed byArechiga Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameDutra Richmond
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Dutra Richmond
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedjobsite
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-09-20-57
DIME Test ID: 2025-09-20-57-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2026-10-26

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Ignacio Arechiga
Date of test: 09/23/2025
Cumulative Mass RetainedCumulative Percent Passing
7678.0 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
116.0 grams98 %
1492.0 grams81 %
2606.0 grams66 %
4546.0 grams41 %
503.1 grams
186.0 grams26 %
276.0 grams19 %
321.0 grams15 %
358.0 grams12 %
394.0 grams9 %
421.3 grams6.7 %
0.0 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/26/2026 ✔