Summary for Test 2026-03-24-13-1

Test performed: CTM 216-June 2011

Project Information

Project IdentifiersProject ID: 1001246
DEA: 041Q7214
EFIS: 0423000277
DIST-CO-RTE-PM04-CC,CC,SOL-580,680,780-Var
Award Date09/25/2025
Closeout DateNot set
Work DescriptionINSTALL FIBER OPTIC CABLE SYSTEM, RAMP METERING, AND WIDEN ROADWAY.
Location DescriptionALAMEDA, CONTRA COSTA AND SOLANO COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 08/13/2025)

Sample Information

Sample Taken Date03/24/2026 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/24/2026
Sample typeQuality Assurance A brief description of the sampleSBF
The quantity of what the sample constitutes50 SQ YDs From where was the sample collectedJob Site
First name of sampler or witnessed byHENRY Last name of sampler or witnessed byCONCEPCION
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePEI Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedRW 26 A -I680 near stone valley rd, danville
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2026-03-24-13
DIME Test ID: 2026-03-24-13-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2026-03-24

Test Results


Is oversize material: No
Input Type: Calculated
Tester's full name: ANTHONY VALDEZ
Date of test: 03/24/2026
In-place wet density: 2.17
Highest adjust wet density: 2.26
% Moisture: 13.6 %
Optimum Moisture: 12.0 %
Relative compaction: 96
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/24/2026