Summary for Test 2018-02-12-3-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 211819
DEA: 080G7704
EFIS: 0814000175
DIST-CO-RTE-PM08-RIV-15-0.00/41.80
Award Date07/14/2017
Closeout Date09/04/2019
Work DescriptionINSTALL TMS FIELD ELEMENTS
Location DescriptionRIVERSIDE COUNTY FROM SAN DIEGO COUNTY LINE TO 1.0 MILE NORTH OF ROUTE 15 / 91 SEPARATION
QA Service Level1 (Verified on 03/20/2018)

Sample Information

Sample Taken Date02/12/2018 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing02/14/2018 Sample typeQuality Control
A brief description of the sample6X12 The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byARNEL
Last name of sampler or witnessed byVEGA Title of samplerSR
Telephone number of samplerUnknown Laboratory sample identification973-212
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameROBERTSONS
Transportation Laboratory (TL) Number20180212 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierSTA F 1069 30 Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSC590B38
The truck number from where the sample was collected1946 The batch plant ticket number from where the sample was collected3370914
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedTAIL Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2018-02-12-3
DIME Test ID: 2018-02-12-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-02-20

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 02/20/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 69670 lb
Maximum load on cylinder 2: 71440 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 8 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 2448.0 psi
Compressive strength of cylinder 2: 2510.2 psi
Compressive strength (to nearest 10 psi): 2480 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2018 ✔