Summary for Test 2026-03-11-57-1

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 1002021
DEA: 023J5704
EFIS: 0222000060
DIST-CO-RTE-PM02-SHA-5-56.7/66.5
Award DateNot set
Closeout DateNot set
Work DescriptionFlume Creek Leftover Culverts Replace/Install Culverts - Fish Passage
Location DescriptionIn Shasta County at various locations from 0.7 mile south of Sims Road Undercrossing to 0.3 miles south of Crag View Drive Undercrossing.
QA Service Level1 (Verified on 03/23/2026)

Sample Information

Sample Taken Date03/11/2026 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/12/2026
Sample typePreliminary A brief description of the sampleSand, Silt, Rock and Soil
The quantity of what the sample constitutesNot Provided From where was the sample collectedSource
First name of sampler or witnessed byDerek Last name of sampler or witnessed bySerna
Title of samplerMREA Telephone number of sampler
Laboratory sample identificationD80154 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCulvert Outlet Transportation Laboratory (TL) Number845684
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedC-8
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2026-03-11-57
DIME Test ID: 2026-03-11-57-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2026-03-24

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 03/18/2026
Minimum soil resistance of the lab measurement: 6800 Ohms
Soil sample temperature: 22.5 C
Soil box constant: 1
pH of soil: 6.83
Minimum soil resistance corrected to 15.5: 7990 Ohm-cm
Minimum soil resistivity at 15.5: 7990 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=6.83, p=7990.Ω∙cm

Test was verified on 3/24/2026