Summary for Test 2026-03-11-50-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 1002021 DEA: 023J5704 EFIS: 0222000060 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-5-56.7/66.5 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Flume Creek Leftover Culverts Replace/Install Culverts - Fish Passage |
| Location Description | In Shasta County at various locations from 0.7 mile south of Sims Road Undercrossing to 0.3 miles south of Crag View Drive Undercrossing. |
| QA Service Level | 1 (Verified on 03/23/2026) |
Sample Information
| Sample Taken Date | 03/11/2026 | Sample Unique Key | 50 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/12/2026 | Sample type | Preliminary |
| A brief description of the sample | Sand, Silt, Rock and Soil | The quantity of what the sample constitutes | Not Provided |
| From where was the sample collected | Source | First name of sampler or witnessed by | Derek |
| Last name of sampler or witnessed by | Serna | Title of sampler | MREA |
| Telephone number of sampler | Laboratory sample identification | D80147 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Culvert Outlet | |
| Transportation Laboratory (TL) Number | 845677 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | C-1 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-03-11-50
DIME Test ID: 2026-03-11-50-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2026-03-24
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 03/17/2026
Minimum soil resistance of the lab measurement: 8100 Ohms
Soil sample temperature: 23.4 C
Soil box constant: 1
pH of soil: 7.08
Minimum soil resistance corrected to 15.5: 9699.75 Ohm-cm
Minimum soil resistivity at 15.5: 9700 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=7.08, p=9700.Ω∙cm
Test was verified on 3/24/2026 ✔