Summary for Test 2025-10-21-75-2

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 1000781
DEA: 040P9304
EFIS: 0418000027
DIST-CO-RTE-PM04-CC-80-7.6,12.8
Award Date03/19/2025
Closeout DateNot set
Work DescriptionBRIDGE RAILING, MVP, CURB & GUTTER, SIDEWALKS, & ELECTRICAL SYSTEMS.
Location DescriptionCONTRA COSTA COUNTY IN PINOLE AT APPIAN WAY OVERCROSSING AND NEAR HERCULES AT CUMMINGS SKYWAY OVERCROSSING.
QA Service Level1 (Verified on 12/27/2024)

Sample Information

Sample Taken Date10/21/2025 Sample Unique Key75
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/21/2025
Sample typeQuality Assurance A brief description of the samplePCC Gradation
The quantity of what the sample constitutes2 bags From where was the sample collectedSource
First name of sampler or witnessed byJose Last name of sampler or witnessed byRuiz
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCentral Sugar City Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Central Sugar City
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-10-21-75
DIME Test ID: 2025-10-21-75-2
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-04-08

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Jose Amparan Ruiz
Date of test: 10/21/2025
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
502 grams
0.0 grams100 %
13.0 grams97 %
91.6 grams82 %
174.8 grams65 %
268.6 grams46 %
395.0 grams21 %
468.6 grams7 %
491.2 grams2 %
0.0 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/8/2026