Summary for Test 2023-06-21-102-1
Test performed: ASTM C136-19Project Information
| Project Identifiers | Project ID: 993446 DEA: 120J34U4 EFIS: 1218000034 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-55,55-29.6,R6.4/10.3 |
| Award Date | 05/27/2022 |
| Closeout Date | Not set |
| Work Description | CONSTR BRIDGES, RW, SW, JPCP, HMA PVMT, DRAINAGE AND ELECT SYSTEMS. |
| Location Description | ORANGE COUNTY IN IRVINE, SANTA ANA, AND TUSTIN ON ROUTE 5 AT NEWPORT AVENUE UNDERCROSSING AND ON ROUTE 55 FROM 0.4 MILE NORTH OF ROUTE 55/405 SEPARATION TO 0.1 MILE SOUTH OF ROUTE 5/55 SEPARATION |
| QA Service Level | 1 (Verified on 06/24/2022) |
Sample Information
| Sample Taken Date | 06/21/2023 | Sample Unique Key | 102 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/21/2023 | Sample type | Quality Control |
| A brief description of the sample | 1 Bucket of 1/2", 1 Bucket of 3/8", 1 Bucket of Sand | The quantity of what the sample constitutes | 1 Bucket of 1/2", 1 Bucket of 3/8", 1 Bucket of Sand |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Patrick |
| Last name of sampler or witnessed by | Baddu | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Con-Fab California, LLC - Shafter | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Con-Fab California, LLC - Shafter |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile @ Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-06-21-102
DIME Test ID: 2023-06-21-102-1
Testing Lab: Con-Fab California Corporation - Shafter
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-03-23
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Has the fine aggregate sample been reduced? (question for combined gradation type): Yes
Input Type: Calculated
Tester's full name: Patrick Baddu
Date of test: 06/21/2023
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 95.4 %
Cumulative percent passing the 3/8 in. sieve: 72.4 %
Cumulative percent passing the #4 sieve: 50.7 %
Cumulative percent passing the #8 sieve: 40.4 %
Cumulative percent passing the #16 sieve: 29.7 %
Cumulative percent passing the #30 sieve: 19.2 %
Cumulative percent passing the #50 sieve: 6.5 %
Cumulative percent passing the #100 sieve: 2.4 %
Cumulative percent passing the #200 sieve: 1.3 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/23/2026 ✔