Summary for Test 2025-10-27-59-1
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 1000567 DEA: 042K7404 EFIS: 0417000018 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-37-R11.2/14.5 |
| Award Date | 12/20/2024 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PVMT, PLACE RHMA AND REPLACE CONCRETE BARRIER. |
| Location Description | MARIN COUNTY IN AND NEAR NOVATO FROM IGNACIO OVERHEAD TO PETALUMA RIVER BRIDGE |
| QA Service Level | 1 (Verified on 10/16/2024) |
Sample Information
| Sample Taken Date | 10/27/2025 | Sample Unique Key | 59 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/23/2026 | Sample type | Production Start-Up |
| A brief description of the sample | 1/2" RHMA-G | The quantity of what the sample constitutes | 20 Boxes RHMA |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Jose Leon |
| Last name of sampler or witnessed by | Amparan | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | D04-SE-26-002 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Materials LH (DP) | |
| Transportation Laboratory (TL) Number | 2026-01-20-01 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 326129 | |
| Binder content (%) | 7.5 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-10-27-59
DIME Test ID: 2025-10-27-59-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-03-22
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Jose Amparan Ruiz
Date of test: 01/23/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7379.8 grams
Mass of oven-dry sample in air for Sample 1: 1544.0 grams
Mass of container filled with the sample and water for Sample 1: 8292.1 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.444
Theoretical maximum density at 25°C (77°F): 2437 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/22/2026 ✔