Summary for Test 2026-03-20-9-1
Test performed: CTM 216-June 2011Project Information
| Project Identifiers | Project ID: 1001910 DEA: 044X5304 EFIS: 0426000087 |
|---|---|
| DIST-CO-RTE-PM | 04-NAP-29-23.54/23.54 |
| Award Date | 10/15/2025 |
| Closeout Date | Not set |
| Work Description | REMOVE AND EXISTING CULVERT AND REPLACE WITH CAST IN PLACE BOX CULVERT AND REPAIR ROADWAY REPLACE CULVERT AND REPAIR ROADWAY |
| Location Description | IN NAPA CO. HWY 29 PM 23.54 |
| QA Service Level | 1 (Verified on 01/16/2026) |
Sample Information
| Sample Taken Date | 03/20/2026 | Sample Unique Key | 9 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/20/2026 | Sample type | Quality Assurance |
| A brief description of the sample | AB2 | The quantity of what the sample constitutes | 80 sq yds |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Christian |
| Last name of sampler or witnessed by | Sousa | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Napa | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Culvert | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-03-20-9
DIME Test ID: 2026-03-20-9-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2026-03-20
Test Results
Is oversize material: No
Input Type: Calculated
Tester's full name: Cody Cordero
Date of test: 03/20/2026
In-place wet density: 2.20
Highest adjust wet density: 2.28
% Moisture: 11.1 %
Optimum Moisture: 12.0 %
Relative compaction: 97
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/20/2026 ✔