Summary for Test 2026-03-13-24-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 1000640 DEA: 074P8504 EFIS: 0719000259 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-1-1.0/1.3 |
| Award Date | 11/20/2024 |
| Closeout Date | Not set |
| Work Description | INSTALL MARKED CROSSWALK WITH PEDESTRIAN HYBRID BEACON SIGNALS. |
| Location Description | VENTURA COUNTY FROM 0.1 MILE SOUTH OF YERBA BUENA ROAD TO 0.1 MILE NORTH OF LITTLE SYCAMORE CREEK BRIDGE |
| QA Service Level | 1 (Verified on 09/24/2024) |
Sample Information
| Sample Taken Date | 03/13/2026 | Sample Unique Key | 24 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/14/2026 |
| Sample type | Acceptance | A brief description of the sample | 4x8 concrete cylinders (3 total) |
| The quantity of what the sample constitutes | 130 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Armando | Last name of sampler or witnessed by | Serratos |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 26-048 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | State Ready Mix | Transportation Laboratory (TL) Number | 3112026 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 590SN2010 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 90166 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | wheelbarrow | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2026-03-13-24
DIME Test ID: 2026-03-13-24-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-03-20
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 03/20/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.02 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 39020 lb
Maximum load on cylinder 2: 36067 lb
Maximum load on cylinder 3: 36758 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.69 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 3089.5 psi
Compressive strength of cylinder 2: 2842.2 psi
Compressive strength of cylinder 3: 2910.4 psi
Compressive strength (to nearest 10 psi): 2950 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/20/2026 ✔