Summary for Test 2026-02-20-6-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000320
DEA: 11430324
EFIS: 1118000102
DIST-CO-RTE-PM11-SD-805-14.6/23.7
Award Date08/23/2024
Closeout DateNot set
Work DescriptionMODIFY ELECTRICAL, CONCRETE PAVEMENT, DRAINAGE AND SIGNS.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM ROUTE 805/15 SEPARATION TO 0.1 MILE NORTH OF ROUTE 805/52 SEPARATION
QA Service Level1 (Verified on 09/09/2024)

Sample Information

Sample Taken Date02/20/2026 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/20/2026
Sample typePreliminary A brief description of the sampleCylinders
The quantity of what the sample constitutesTrial Batch From where was the sample collectedJob Site
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byCordero
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameShortload Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-72-EHI
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedTrial Batch Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-02-20-6
DIME Test ID: 2026-02-20-6-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-03-20

Test Results


Unit system used?: US Units
Number of specimens: 4
Test performed: With no density determined
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 03/20/2026
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 5.96 in
Average diameter of cylinder 2: 5.97 in
Average diameter of cylinder 3: 5.97 in
Average diameter of cylinder 4: 5.98 in
Maximum load on cylinder 1: 253330 lb
Maximum load on cylinder 2: 252940 lb
Maximum load on cylinder 3: 251640 lb
Maximum load on cylinder 4: 252105 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Type of fracture pattern of cylinder 4: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Correction factor for cylinder 4: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 27.9 in^2
Cross sectional area of cylinder 2: 27.99 in^2
Cross sectional area of cylinder 3: 27.99 in^2
Cross sectional area of cylinder 4: 28.09 in^2
Compressive strength of cylinder 1: 9079.9 psi
Compressive strength of cylinder 2: 9036.8 psi
Compressive strength of cylinder 3: 8990.4 psi
Compressive strength of cylinder 4: 8974.9 psi
Compressive strength (to nearest 10 psi): 9020 psi
General comments (publicly viewable) (Max 1000 characters): 28 Day, Complies 5350 @ 28 days

Test was verified on 3/20/2026