Summary for Test 2026-03-10-45-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 214649 DEA: 07316004 EFIS: 0715000194 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-14-60.70 |
| Award Date | 02/07/2023 |
| Closeout Date | Not set |
| Work Description | REHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES. |
| Location Description | ROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE. |
| QA Service Level | 1 (Verified on 01/29/2020) |
Sample Information
| Sample Taken Date | 03/10/2026 | Sample Unique Key | 45 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/10/2026 | Sample type | Quality Assurance |
| A brief description of the sample | Existing Subgrade | The quantity of what the sample constitutes | 1575 CY |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Mike |
| Last name of sampler or witnessed by | Dillon | Title of sampler | Field Technician |
| Telephone number of sampler | 909-701-8239 | Laboratory sample identification | 26-0877 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Existing Subgrade | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | CTM 231 test location | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-03-10-45
DIME Test ID: 2026-03-10-45-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-03-19
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: Mike Dillon
Date of test: 03/10/2026
Sum of Count or Density: 40757 g/cc
Average of Count or Density: 8151 g/cc
Sum of Moisture Count: 16092 g/cc
Average of Moisture Count: 3218 g/cc
Count Ratio Density: 2.12
Count Ratio Moisture: 0.14
Calculated Percent Relative Compaction: 94.6 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/19/2026 ✔