Summary for Test 2018-02-08-7-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 209146
DEA: 06471504
EFIS: 0600000464
COOP: 061549
DIST-CO-RTE-PM06-TUL-99-39.6/41.3
Award Date02/24/2017
Closeout Date03/03/2020
Work DescriptionRECONSTRUCT INTERCHANGE WITH NEW PUMPING PLANT.
Location DescriptionTULARE COUNTY AT GOSHEN FROM 0.9 MILE NORTH OF ROUTE 99/198 WEST SEPARATION TO 0.2 MILE NORTH OF NORTH GOSHEN OVERHEAD
QA Service Level1 (Verified on 10/08/2013)

Sample Information

Sample Taken Date02/08/2018 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing02/13/2018 Sample typeRetest
A brief description of the sampleDuctile Iron Casting The quantity of what the sample constitutes1
From where was the sample collectedManufacturer First name of sampler or witnessed byDebbie
Last name of sampler or witnessed byOzuna Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameUnknown
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)3547
Part Number (s)68 19 246 Material SpecificationA536
Grades65-45-12 Metal Foundry Manufacturer (Mill)Dickson Iron Casting
Prestressing ManufacturerDywidag Systems

Test Details

DIME Sample ID: 2018-02-08-7
DIME Test ID: 2018-02-08-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2018-02-22

Test Results


Number of Samples: 1
Input Type: Calculated
Tester's full name: Fred
Date of test: 02/15/2018
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
135470.5040.1995425777077021.3Fred

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 2/15/2018 ✔