Summary for Test 2026-02-06-43-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 995534 DEA: 120T8604 EFIS: 1222000109 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5-2.3/19.9 |
| Award Date | 03/13/2024 |
| Closeout Date | 06/22/2026 |
| Work Description | APPLY METHACRYLATE AND POLYESTER CONCRETE & REPLACE JOINT SEALS. |
| Location Description | ORANGE COUNTY AT VARIOUS LOCATIONS FROM AVENIDA PRESIDIO UNDERCROSSING TO LAKE FOREST DRIVE OVERCROSSING |
| QA Service Level | 1 (Verified on 01/26/2024) |
Sample Information
| Sample Taken Date | 02/06/2026 | Sample Unique Key | 43 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/12/2026 | Sample type | Quality Control |
| A brief description of the sample | #5 rebar coupler samples | The quantity of what the sample constitutes | 12 |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Greg |
| Last name of sampler or witnessed by | Stevens | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Rouch Rebar, Inc. | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | 55-0231 | Structure name | Junipero Serra UC |
| Bid Item | 3888364 |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Cascade |
| Coupler Manufacturer | OCM | Intermediate Assembler or Fabricator | |
| Rebar Size | #5 | Coupler Model | O-S Splice Clip |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 81003123 | Rebar Heat Number(s) | 031226 |
| Rebar Size 2 | Coupler Unique ID | WT-17-01 |
Test Details
DIME Sample ID: 2026-02-06-43
DIME Test ID: 2026-02-06-43-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-03-18
Test Results
Number of Samples: 12
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 03/18/2026
UTM: NA
Temperature: 72 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 5 | 0.31 | 25540 | 82500 | Broke in coupler | Kleinfelder |
| 2 | 2 | 1 | 5 | 0.31 | 25970 | 84000 | Broke in coupler | Kleinfelder |
| 3 | 3 | 1 | 5 | 0.31 | 26230 | 84500 | Broke in coupler | Kleinfelder |
| 4 | 4 | 1 | 5 | 0.31 | 26090 | 84000 | Broke in coupler | Kleinfelder |
| 5 | 5 | 1 | 5 | 0.31 | 26190 | 84500 | Broke in coupler | Kleinfelder |
| 6 | 6 | 1 | 5 | 0.31 | 27020 | 87000 | Broke in coupler | Kleinfelder |
| 7 | 7 | 1 | 5 | 0.31 | 27240 | 88000 | Broke in coupler | Kleinfelder |
| 8 | 8 | 1 | 5 | 0.31 | 27100 | 87500 | Broke in coupler | Kleinfelder |
| 9 | 9 | 1 | 5 | 0.31 | 27100 | 87500 | Broke in coupler | Kleinfelder |
| 10 | 10 | 1 | 5 | 0.31 | 25540 | 82500 | Broke in coupler | Kleinfelder |
| 11 | 11 | 1 | 5 | 0.31 | 26150 | 84500 | Broke in coupler | Kleinfelder |
| 12 | 12 | 1 | 5 | 0.31 | 27430 | 88500 | Broke in coupler | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/18/2026 ✔