Summary for Test 2025-08-25-145-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 1000665
DEA: 081K4004
EFIS: 0819000031
DIST-CO-RTE-PM08-RIV-15-3.5/6.8
Award Date01/29/2025
Closeout DateNot set
Work DescriptionHMA (TYPE A), RDWY EXC, STR CONC RET WALL, RUBBERIZED HMA (OGFC).
Location DescriptionTEMECULA FROM 0.1 MI NORTH OF TEMECULA PARKWAY TO 0.2 MI NORTH OF WINCHESTER ROAD
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date08/25/2025 Sample Unique Key145
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/25/2025
Sample typeAcceptance A brief description of the sampleNative Subgrade
The quantity of what the sample constituteskg From where was the sample collectedJob Site
First name of sampler or witnessed byMaryAnna Last name of sampler or witnessed byLandaverde
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTM 231 TEST LOCATION Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedI-15 SB, Road Widening B/W Winchester Rd & Rancho California Rd, Sta 295+72 - 303+54
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2025-08-25-145
DIME Test ID: 2025-08-25-145-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-03-16

Test Results


Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: Yes
Input Type: Measured
Tester's full name: MaryAnna Landaverde
Date of test: 08/25/2025
Gage No.: 30691
Test No.: 3
Nuclear By: MaryAnna Landaverde
Non-Bias Plan No.: 9
Depth: 8"
Material No.: no data
Material Type: Native Subgrade
Impact By: no data
Standard Count Density: 1593 g/cc
Count or Density 1: 1033 g/cc
Count or Density 2: 940 g/cc
Count or Density 3: 934 g/cc
Count or Density 4: 953 g/cc
Count or Density 5: 971 g/cc
Standard Count Moisture: 649 g/cc
Moisture Count 1: 55 g/cc
Moisture Count 2: 110 g/cc
Moisture Count 3: 59 g/cc
Moisture Count 4: 60 g/cc
Moisture Count 5: 63 g/cc
Density: 2.08
Moisture: 0.08
Sum of Count or Density: 4831 g/cc
Average of Count or Density: 966 g/cc
Sum of Moisture Count: 347 g/cc
Average of Moisture Count: 69 g/cc
Count Ratio Density: 0.61
Count Ratio Moisture: 0.11
Calculated Percent Relative Compaction: 94.3 %
Reported Percent Relative Compaction: 94 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/16/2026