Summary for Test 2025-08-04-133-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 1000665 DEA: 081K4004 EFIS: 0819000031 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-15-3.5/6.8 |
| Award Date | 01/29/2025 |
| Closeout Date | Not set |
| Work Description | HMA (TYPE A), RDWY EXC, STR CONC RET WALL, RUBBERIZED HMA (OGFC). |
| Location Description | TEMECULA FROM 0.1 MI NORTH OF TEMECULA PARKWAY TO 0.2 MI NORTH OF WINCHESTER ROAD |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 08/04/2025 | Sample Unique Key | 133 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/04/2025 |
| Sample type | Acceptance | A brief description of the sample | Class II Aggregate Base |
| The quantity of what the sample constitutes | kg | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Gabriel | Last name of sampler or witnessed by | Ramirez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | I-15 NB ML, North of Rancho California Rd to NB I-15 On-Ramp, Roadway Widening, Sta 316+00 - 318+00 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-08-04-133
DIME Test ID: 2025-08-04-133-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-03-13
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: Yes
Input Type: Measured
Tester's full name: Gabriel Ramirez
Date of test: 08/04/2025
Gage No.: 36636
Test No.: 5
Nuclear By: Gabriel Ramirez
Non-Bias Plan No.: 1
Depth: 5"
Material No.: no data
Material Type: Class II Aggregate Base
Impact By: no data
Standard Count Density: 1716 g/cc
Count or Density 1: 1641 g/cc
Count or Density 2: 1599 g/cc
Count or Density 3: 1595 g/cc
Standard Count Moisture: 644 g/cc
Moisture Count 1: 57 g/cc
Moisture Count 2: 52 g/cc
Moisture Count 3: 59 g/cc
Density: 2.22
Moisture: 0.09
Sum of Count or Density: 4835 g/cc
Average of Count or Density: 1612 g/cc
Sum of Moisture Count: 168 g/cc
Average of Moisture Count: 56 g/cc
Count Ratio Density: 0.94
Count Ratio Moisture: 0.09
Calculated Percent Relative Compaction: 97.8 %
Reported Percent Relative Compaction: 98 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/13/2026 ✔