Summary for Test 2026-03-09-3-5

Test performed: AASHTO T269-24E25

Project Information

Project IdentifiersProject ID: 993812
DEA: 11431274
EFIS: 1121000129
DIST-CO-RTE-PM11-SD-5-R0.3/R36.0
Award Date01/28/2025
Closeout DateNot set
Work DescriptionCMGC Project- Restore the pavement to a state of good repair through roadway rehabilitation, pavement preservation, drainage restoration, transportation management system upgrades, and American with Disabilities Act (ADA) infrastructure improvements.
Location DescriptionSD County
QA Service Level1 (Verified on 09/19/2022)

Sample Information

Sample Taken Date03/09/2026 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/09/2026
Sample typeProduction Start-Up A brief description of the samplePSU
The quantity of what the sample constitutes12 boxes From where was the sample collectedSupplier
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byCordero
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta Lakeside Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number21218180AH
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder SupplierValero
RAP content (%)0 WMA AdditivesNo
Antistrip type

Test Details

DIME Sample ID: 2026-03-09-3
DIME Test ID: 2026-03-09-3-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T269-24E25: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2026-03-30

Test Results


Is the sample lab compacted or field compacted?: Lab compacted
Number of tests: 3
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 03/11/2026
Bulk Specific Gravity: 2.401
Bulk Specific Gravity 2: 2.393
Bulk Specific Gravity 3: 2.394
Theoretical Maximum Specific Gravity: 2.484
Percent Air Voids: 3.3 %
Percent Air Voids 2: 3.7 %
Percent Air Voids 3: 3.6 %
Average Percent Air Voids: 3.5 %
General comments (publicly viewable) (Max 1000 characters): Complies Target 4.0% Air Voids Tested an Avg of 3.5 % Air Voids

Test was verified on 3/30/2026