Summary for Test 2026-01-21-55-1

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 1001329
DEA: 100X7404
EFIS: 1013000008
DIST-CO-RTE-PM10-CAL-12-17.1/17.5
Award Date09/03/2025
Closeout DateNot set
Work DescriptionBRIDGE REPLACEMENT.
Location DescriptionCALAVERAS COUNTY NEAR SAN ANDREAS FROM 0.2 MILE WEST OF NORTH FORK CALAVERAS RIVER BRIDGE TO 0.2 MILE EAST OF NORTH CALAVERAS RIVER BRIDGE
QA Service Level1 (Verified on 06/16/2025)

Sample Information

Sample Taken Date01/21/2026 Sample Unique Key55
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/03/2026
Sample typeQuality Assurance A brief description of the sample6/10" PT Strand
The quantity of what the sample constitutes14 From where was the sample collectedManufacturer
First name of sampler or witnessed byNA Last name of sampler or witnessed byNA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)S381088-1D, S381089-7, S381093-6, S381096-7, S381098-2 Number of Coils
Group Number Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0520625, S0506025, S0553925, S0552925, S0553325-2 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden

Test Details

DIME Sample ID: 2026-01-21-55
DIME Test ID: 2026-01-21-55-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-03-17

Test Results


Number of Samples: 5
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 03/11/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0520625S381088-1D0.217592705730029.60Atlas
2S0506025S381089-70.217601005688029.50Atlas
3S0553925S381093-60.217601405740028.80Atlas
4S0552925S381096-70.2176139055850280Atlas
5S0553325-2S381098-20.217612305700028.80Atlas

General comments (publicly viewable) (Max 1000 characters): Elongation Passed on All

Test was verified on 3/17/2026