Summary for Test 2025-08-13-143-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994864
DEA: 050N74U4
EFIS: 0522000025
DIST-CO-RTE-PM05-SB-101-9.9/10.6
Award Date07/10/2023
Closeout DateNot set
Work DescriptionSB 101 4D North San Ysidro to Olive Mill
Location DescriptionIn Santa Barbara County in and near Santa Barbara from 0.1 mile south of San Ysidro Road Overcrossing to 0.1 north of Olive Mill Road Overcrossing
QA Service Level1 (Verified on 08/21/2023)

Sample Information

Sample Taken Date08/13/2025 Sample Unique Key143
Date that the sample was received by the laboratory/organization performing the testing08/14/2025 Sample typeQuality Control
A brief description of the samplestructural concrete The quantity of what the sample constitutes1 per batch
From where was the sample collectedJob Site First name of sampler or witnessed byharrison
Last name of sampler or witnessed bykain Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namecemex santa barbara
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1627309
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected31709060
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedRW 109 Soldier Piles Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-08-13-143
DIME Test ID: 2025-08-13-143-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-03-11

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Ryan Montanez
Date of test: 09/10/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 245430 lb
Maximum load on cylinder 2: 225160 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 8320 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/11/2026 ✔