Summary for Test 2026-02-28-13-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1001440
DEA: 07370804
EFIS: 0720000139
DIST-CO-RTE-PM07-LA-5-30.6/31.6
Award DateNot set
Closeout DateNot set
Work DescriptionREMOVE CONCRETE PAVEMENT AND BASE, AND PLACE JPCP.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM 0.2 MILE NORTH OF SAN FERNANDO BOULEVARD TO 0.2 MILE SOUTH OF COHASSET STREET
QA Service Level1 (Verified on 08/15/2025)

Sample Information

Sample Taken Date02/28/2026 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/28/2026
Sample typeAcceptance A brief description of the sample6X12 PCC cylinders
The quantity of what the sample constitutes130 CY From where was the sample collectedJob Site
First name of sampler or witnessed byAlice Last name of sampler or witnessed byAchuela
Title of samplerG3 QC technician Telephone number of sampler5627941732
Laboratory sample identification26-0754 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNational Ready Mix Concrete Company Transportation Laboratory (TL) Number26-0754
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberO85C436L0
The truck number from where the sample was collected1 The batch plant ticket number from where the sample was collected217819
Concrete batch plantNational Ready Mix Concrete Company The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-02-28-13
DIME Test ID: 2026-02-28-13-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-03-11

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Robert Achuela
Date of test: 03/10/2026
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Average diameter of cylinder 3: 6.01 in
Maximum load on cylinder 1: 167053 lb
Maximum load on cylinder 2: 183018 lb
Maximum load on cylinder 3: 171463 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 10 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Cross sectional area of cylinder 3: 28.37 in^2
Compressive strength of cylinder 1: 5888.4 psi
Compressive strength of cylinder 2: 6451.1 psi
Compressive strength of cylinder 3: 6043.8 psi
Compressive strength (to nearest 10 psi): 6130 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/11/2026