Summary for Test 2026-01-22-82-3

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 1001957
DEA: 021K7204
EFIS: 0224000158
DIST-CO-RTE-PM02-SHA-273-5.2/14.5
Award Date11/21/2028
Closeout DateNot set
Work DescriptionBrighter 273 Safety - Install lighting
Location DescriptionIn Shasta County from 0.1 mile North of Anderson Creek bridge in Anderson to 0.1 North of Buenaventura Boulevard in Redding 6/17/24 JC
QA Service Level1 (Verified on 02/17/2026)

Sample Information

Sample Taken Date01/22/2026 Sample Unique Key82
Date that the sample was received by the laboratory/organization performing the testing01/27/2026 Sample typePreliminary
A brief description of the sample2 Bags of Rock and Soil The quantity of what the sample constitutesStructural Section Recommendation
From where was the sample collectedSource First name of sampler or witnessed byDerek
Last name of sampler or witnessed bySerna Title of samplerMREA
Telephone number of sampler Laboratory sample identificationD80139
Linked DIME Sample ID The fabricator/manufacturer/facility nameDistrict 2 Lab
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedShoulder Slope near PM 8.0
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2026-01-22-82
DIME Test ID: 2026-01-22-82-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2026-03-10

Test Results


Number of tests: 3
Input Type: Measured
Tester's full name: Dacota Mei
Date of test: 02/24/2026
Temperature correction: 0
Temperature of solution: 22
Clay reading (test 1): 11.9
Sand reading (test 1): 1.7
Clay reading (test 2): 12.1
Sand reading (test 2): 1.7
Clay reading (test 3): 12.3
Sand reading (test 3): 1.8
Sand equivalent (test 1): 15
Sand equivalent (test 2): 14
Sand equivalent (test 3): 15
Sand equivalent before temperature correction: 15
Sand equivalent after temperature correction: 15
General comments (publicly viewable) (Max 1000 characters): SE=15

Test was verified on 3/10/2026 ✔