Summary for Test 2026-02-28-8-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 1001440 DEA: 07370804 EFIS: 0720000139 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-30.6/31.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | REMOVE CONCRETE PAVEMENT AND BASE, AND PLACE JPCP. |
| Location Description | LOS ANGELES COUNTY IN BURBANK FROM 0.2 MILE NORTH OF SAN FERNANDO BOULEVARD TO 0.2 MILE SOUTH OF COHASSET STREET |
| QA Service Level | 1 (Verified on 08/15/2025) |
Sample Information
| Sample Taken Date | 02/28/2026 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/28/2026 |
| Sample type | Quality Assurance | A brief description of the sample | LCB-RSC |
| The quantity of what the sample constitutes | 40 CY of 640 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Marcus | Last name of sampler or witnessed by | Molina |
| Title of sampler | Field Technician | Telephone number of sampler | 909-534-3477 |
| Laboratory sample identification | 26-0738 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | National Ready Mix - Sun Valley | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | S67C741L0 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 319716 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Revolving drum (tailgate) | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2026-02-28-8
DIME Test ID: 2026-02-28-8-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-03-10
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Michael Magana
Date of test: 03/07/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 192584 lb
Maximum load on cylinder 2: 189707 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 6760 psi
General comments (publicly viewable) (Max 1000 characters):