Summary for Test 2026-03-03-17-1

Test performed: CTM 202-November 2011
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.

Project Information

Project IdentifiersProject ID: 994901
DEA: 112T3434
EFIS: 1120000081
DIST-CO-RTE-PM11-SD-805-5.1/8.3
Award Date01/29/2024
Closeout DateNot set
Work DescriptionSOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL.
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING
QA Service Level1 (Verified on 03/21/2024)

Sample Information

Sample Taken Date03/03/2026 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing03/03/2026 Sample typeQuality Assurance
A brief description of the sampleConcrete Aggregates The quantity of what the sample constitutes3 bags
From where was the sample collectedJob Site First name of sampler or witnessed byMohammed
Last name of sampler or witnessed byMasud Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAssociated Otay
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Not Provided
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number556300 Lot number
Sublot number Aggregate Mix Number

Combined Gradation Report Information

Combined Gradation Report IdBin IndexDime Test Id
2026-03-7: PCC Aggregates (Size 1"): Sieve Analysis12026-03-03-17-1

Test Details

DIME Sample ID: 2026-03-03-17
DIME Test ID: 2026-03-03-17-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-03-10

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 03/06/2026
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
14426 grams
0.0 grams100 %
519.0 grams96 %
7338.0 grams49 %
14156.0 grams2 %
14312.0 grams1 %
14326.0 grams1 %
14332.0 grams1 %
14386.0 grams
General comments (publicly viewable) (Max 1000 characters): 1", Complies

Test was verified on 3/11/2026 ✔

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.