Summary for Test 2026-03-02-5-3

Test performed: AASHTO T269-24E25

Project Information

Project IdentifiersProject ID: 1001213
DEA: 11431644
EFIS: 1122000232
DIST-CO-RTE-PM11-SD-78-N17.7
Award DateNot set
Closeout DateNot set
Work DescriptionCold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location DescriptionIN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
QA Service Level1 (Verified on 05/07/2025)

Sample Information

Sample Taken Date03/02/2026 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/02/2026
Sample typeQuality Assurance A brief description of the sampleDaily Production
The quantity of what the sample constitutes2 boxes From where was the sample collectedSupplier
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byCordero
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta Lakeside Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number23418180AH
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder SupplierValero
RAP content (%)0 WMA AdditivesNo
Antistrip type

Test Details

DIME Sample ID: 2026-03-02-5
DIME Test ID: 2026-03-02-5-3
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T269-24E25: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2026-03-06

Test Results


Is the sample lab compacted or field compacted?: Lab compacted
Number of tests: 3
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 03/03/2026
Bulk Specific Gravity: 2.379
Bulk Specific Gravity 2: 2.380
Bulk Specific Gravity 3: 2.381
Theoretical Maximum Specific Gravity: 2.45
Percent Air Voids: 2.9 %
Percent Air Voids 2: 2.9 %
Percent Air Voids 3: 2.8 %
Average Percent Air Voids: 2.9 %
General comments (publicly viewable) (Max 1000 characters): Complies

Test was verified on 3/6/2026