Summary for Test 2026-02-05-45-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 993798 DEA: 09366804 EFIS: 0916000021 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-395-117.3/117.9 |
| Award Date | 04/03/2025 |
| Closeout Date | Not set |
| Work Description | MEADOW FARMS ADA |
| Location Description | INYO COUNTY NEAR BISHOP FROM 0.1 MILE EAST OF SEE VEE LANE TO BARLOW LANE |
| QA Service Level | 1 (Verified on 08/14/2023) |
Sample Information
| Sample Taken Date | 02/05/2026 | Sample Unique Key | 45 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/06/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 4 PCC Cylinders 6x12 |
| The quantity of what the sample constitutes | 9 Yds | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Darrell | Last name of sampler or witnessed by | Biederman |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | PCC-004 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | 7/11 Materials | Transportation Laboratory (TL) Number | 5272 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Pedestrian Bridge | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 00 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | First 1/4 of truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2026-02-05-45
DIME Test ID: 2026-02-05-45-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-03-05
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 03/05/2026
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 174650 lb
Maximum load on cylinder 2: 176390 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 6156.2 psi
Compressive strength of cylinder 2: 6217.5 psi
Compressive strength (to nearest 10 psi): 6190 psi
General comments (publicly viewable) (Max 1000 characters): PCC-004 28 Day Break
Test was verified on 3/5/2026 ✔