Summary for Test 2026-02-04-60-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000802
DEA: 07346804
EFIS: 0718000079
DIST-CO-RTE-PM07-VEN-232-0.4/R4.1
Award Date02/04/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AND OVERLAY WITH HMA & RHMA.
Location DescriptionVENTURA COUNTY IN AND NEAR OXNARD FROM ROUTE 232/101 SEPARATION TO ROUTE 118
QA Service Level1 (Verified on 01/27/2025)

Sample Information

Sample Taken Date02/04/2026 Sample Unique Key60
Date that the sample was received by the laboratory/organization performing the testing02/05/2026 Sample typeQuality Assurance
A brief description of the sampleLCBRSC The quantity of what the sample constitutes60 CY of 186 CY
From where was the sample collectedJob Site First name of sampler or witnessed byMike
Last name of sampler or witnessed byDillon Title of samplerField Technician
Telephone number of sampler909-701-8239 Laboratory sample identification26-0461
Linked DIME Sample ID The fabricator/manufacturer/facility nameGeorge L Throop Co.
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number2024-LCBRS
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected6
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedVolumetric Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-02-04-60
DIME Test ID: 2026-02-04-60-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-03-05

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jeffrey Diaz
Date of test: 02/11/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 31834 lb
Maximum load on cylinder 2: 31553 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength (to nearest 10 psi): 1120 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/5/2026 ✔