Summary for Test 2025-09-28-21-1
Test performed: ASTM D36-14ε1Project Information
| Project Identifiers | Project ID: 995060 DEA: 081J2604 EFIS: 0818000012 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-215-R13.5/R19.5 |
| Award Date | 01/10/2024 |
| Closeout Date | 01/21/2026 |
| Work Description | RHMA, REPLACE AC SURFACING, ROCK BLANKET, AND COMPOST. |
| Location Description | RIVERSIDE COUNTY IN MURRIETA AND MENIFEE FROM 1.0 MILE NORTH OF CLINTON KEITH ROAD TO 1.0 MILE NORTH OF NEWPORT ROAD |
| QA Service Level | 1 (Verified on 08/15/2023) |
Sample Information
| Sample Taken Date | 09/28/2025 | Sample Unique Key | 21 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/01/2025 | Sample type | Verification |
| A brief description of the sample | Asphalt Rubber Binder | The quantity of what the sample constitutes | 1can |
| From where was the sample collected | Source | First name of sampler or witnessed by | Thomas |
| Last name of sampler or witnessed by | GULIEMANA | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | RJ Noble-Corona | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2025-09-28-21
DIME Test ID: 2025-09-28-21-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2026-03-04
Test Results
ASTM Thermometer used?: C
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 03/02/2026
Softening Point Sample 1: 63 C
Softening Point Sample 2: 63 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/4/2026 ✔