Summary for Test 2018-01-08-3-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 211797
DEA: 080G8424
EFIS: 0814000184
DIST-CO-RTE-PM08-SBD-15-R107.3
Award Date12/29/2016
Closeout Date06/23/2021
Work DescriptionUPGRADE EXISTING SAFETY ROADSIDE REST AREAS (SRRA)
Location DescriptionSAN BERNARDINO COUNTY ABOUT 30 MILES EAST OF BARSTOW AT C.V. KANE SAFETY ROADSIDE REST AREA
QA Service Level1 (Verified on 02/08/2017)

Sample Information

Sample Taken Date01/08/2018 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing01/15/2018 Sample typeQuality Control
A brief description of the sample6X12 The quantity of what the sample constitutes2
From where was the sample collectedJob Site First name of sampler or witnessed byKAMMAL
Last name of sampler or witnessed byUDDIN Title of samplerASR
Telephone number of samplerUnknown Laboratory sample identification961-5B
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameROBERTSONS
Transportation Laboratory (TL) Number5B Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierSB CV KANE SAFETY ROADSIDE REST AREA Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSM400B34
The truck number from where the sample was collected1195 The batch plant ticket number from where the sample was collected2672929
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedCHUTE Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2018-01-08-3
DIME Test ID: 2018-01-08-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-02-05

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 02/05/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 151680 lb
Maximum load on cylinder 2: 155235 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 5346.5 psi
Compressive strength of cylinder 2: 5491.2 psi
Compressive strength (to nearest 10 psi): 5420 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/5/2018 ✔