Summary for Test 2026-02-12-36-6

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 1000781
DEA: 040P9304
EFIS: 0418000027
DIST-CO-RTE-PM04-CC-80-7.6,12.8
Award Date03/19/2025
Closeout DateNot set
Work DescriptionBRIDGE RAILING, MVP, CURB & GUTTER, SIDEWALKS, & ELECTRICAL SYSTEMS.
Location DescriptionCONTRA COSTA COUNTY IN PINOLE AT APPIAN WAY OVERCROSSING AND NEAR HERCULES AT CUMMINGS SKYWAY OVERCROSSING.
QA Service Level1 (Verified on 12/27/2024)

Sample Information

Sample Taken Date02/12/2026 Sample Unique Key36
Date that the sample was received by the laboratory/organization performing the testing02/13/2026 Sample typeQuality Control
A brief description of the sample1 coarse 1 fine The quantity of what the sample constitutes2 Bags
From where was the sample collectedSupplier First name of sampler or witnessed byjose
Last name of sampler or witnessed byleon Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex Concord
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Cemex
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-02-12-36
DIME Test ID: 2026-02-12-36-6
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-02-25

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Casey
Date of test: 02/13/2026
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
517 grams
0.0 grams100 %
12.0 grams98 %
102.0 grams80 %
195.0 grams62 %
298.0 grams42 %
422.0 grams18 %
510.0 grams1 %
513.0 grams1 %
517.0 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/25/2026 ✔