Summary for Test 2026-02-23-7-4

Test performed: CTM TEMP1-16

Project Information

Project IdentifiersProject ID: 1000403
DEA: 120K91U4
EFIS: 1222000031
DIST-CO-RTE-PM12-ORA-91-R9.2/R11.4
Award Date01/03/2025
Closeout DateNot set
Work DescriptionCONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location DescriptionORANGE COUNTY IN ANAHEIM FROM 0.9 MILE WEST TO 1.3 MILES EAST OF LAKEVIEW AVENUE OVERCROSSING
QA Service Level1 (Verified on 08/19/2024)

Sample Information

Sample Taken Date02/23/2026 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing02/23/2026 Sample typeQuality Control
A brief description of the sampleT-II/V Cement The quantity of what the sample constitutes4.77 CY
From where was the sample collectedFabricator First name of sampler or witnessed byBenjamin
Last name of sampler or witnessed byAragon Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCon-Fab California, LLC - Shafter
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSCC-S9.8-FG
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected6940
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSampled from wheelbarrow collected from chute of ready mix truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-02-23-7
DIME Test ID: 2026-02-23-7-4
Testing Lab: Con-Fab California Corporation - Shafter
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Test Release Date: 2026-02-24

Test Results


Input Type: Calculated
Tester's full name: Benjamin Aragon
Date of test: 02/23/2026
Precast Maximum Curing Temperature: 149 °F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/24/2026 ✔