Summary for Test 2025-07-23-139-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 1000889 DEA: 081M7404 EFIS: 0822000036 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-210-1.2/1.6 |
| Award Date | 03/12/2025 |
| Closeout Date | Not set |
| Work Description | JPCP (RSC), RDWY EXC, LCB RAPID SETTING, & HMA (TYPE A). |
| Location Description | SANBERNARDINO COUNTY IN UPLAND FROM 0.3 MILE WEST TO 0.1 MILE EAST OF MOUNTAIN AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 07/23/2025 | Sample Unique Key | 139 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/23/2025 |
| Sample type | Acceptance | A brief description of the sample | Class II Aggregate Base |
| The quantity of what the sample constitutes | 25.7 kg | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Gabriel | Last name of sampler or witnessed by | Ramirez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | SR-210 WB Right Shoulder near Mountain Ave Overcrossing Bridge, Sta 398+70 - 406+00 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-07-23-139
DIME Test ID: 2025-07-23-139-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-02-24
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Gabriel Ramirez
Date of test: 07/23/2025
Gage No.: 36636
Test No.: 1
Nuclear By: Gabriel Ramirez
Non-Bias Plan No.: 5
Depth: 8"
Material No.: no data
Material Type: Class II Aggregate Base
Impact By: Gabriel Ramirez
Standard Count Density: 1715 g/cc
Count or Density 1: 1030 g/cc
Count or Density 2: 855 g/cc
Count or Density 3: 1005 g/cc
Standard Count Moisture: 648 g/cc
Moisture Count 1: 50 g/cc
Moisture Count 2: 75 g/cc
Moisture Count 3: 47 g/cc
Sum of Count or Density: 2890 g/cc
Average of Count or Density: 963 g/cc
Sum of Moisture Count: 172 g/cc
Average of Moisture Count: 57 g/cc
Count Ratio Density: 0.56
Count Ratio Moisture: 0.09
Calculated Percent Relative Compaction: 98.3 %
Reported Percent Relative Compaction: 98 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/24/2026 ✔
