Summary for Test 2025-08-28-104-6
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 1000256 DEA: 120S2804 EFIS: 1220000014 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5-9.6/10.4 |
| Award Date | 06/24/2024 |
| Closeout Date | 09/01/2026 |
| Work Description | ADD SECONDARY AUXILIARY LANE. |
| Location Description | ORANGE COUNTY IN SAN JUAN CAPISTRANO FROM ROUTE 74/5 SEPARATION TO 0.5 MILE SOUTH OF JUNIPERO SERRA ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 05/14/2024) |
Sample Information
| Sample Taken Date | 08/28/2025 | Sample Unique Key | 104 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/28/2025 | Sample type | Quality Control |
| A brief description of the sample | CIP Aggs | The quantity of what the sample constitutes | 1 per batch |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Rodrigo |
| Last name of sampler or witnessed by | Lupian | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Cemex Irvine | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 00000000 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Belt Cut | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-08-28-104
DIME Test ID: 2025-08-28-104-6
Testing Lab: Sequoia Consultants
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-02-24
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Anthony Bueno
Date of test: 08/29/2025
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 100 % | ||||||
| 98 % | ||||||
| 85 % | ||||||
| 64 % | ||||||
| 42 % | ||||||
| 22 % | ||||||
| 9 % | ||||||
| 3.1 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/24/2026 ✔