Summary for Test 2026-02-04-48-2

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1000665
DEA: 081K4004
EFIS: 0819000031
DIST-CO-RTE-PM08-RIV-15-3.5/6.8
Award Date01/29/2025
Closeout DateNot set
Work DescriptionHMA (TYPE A), RDWY EXC, STR CONC RET WALL, RUBBERIZED HMA (OGFC).
Location DescriptionTEMECULA FROM 0.1 MI NORTH OF TEMECULA PARKWAY TO 0.2 MI NORTH OF WINCHESTER ROAD
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date02/04/2026 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/04/2026
Sample typeAcceptance A brief description of the sample3/4 HMA-SP Type A
The quantity of what the sample constitutes2box From where was the sample collectedSource
First name of sampler or witnessed byJacob Last name of sampler or witnessed byW
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRJ Noble Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-02-04-48
DIME Test ID: 2026-02-04-48-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-02-23

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Ayman Nabulsi
Date of test: 02/10/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2186.6 g
Mass Loss: 117.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.49 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.12 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.78 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/23/2026