Summary for Test 2025-11-13-59-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 1000103
DEA: 081J8604
EFIS: 0818000123
DIST-CO-RTE-PM08-SBD-10,15,40,58,60,etc.-Var
Award Date05/01/2024
Closeout DateNot set
Work DescriptionMODIFYING CMS SYSTEMS AND FURNISH SIGN STRUCTURE (VERSATILE TRUSS).
Location DescriptionSAN BERNARDINO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 05/15/2024)

Sample Information

Sample Taken Date11/13/2025 Sample Unique Key59
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/13/2025
Sample typeAcceptance A brief description of the sampleImported Class II Aggregate Base
The quantity of what the sample constitutes23.7 kg From where was the sample collectedJob Site
First name of sampler or witnessed byDylan Last name of sampler or witnessed byNault
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTM 231 TEST LOCATION Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedWB SR-210, MVP B/W Mountain Ave & Baseline Rd, PM 0.74
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2025-11-13-59
DIME Test ID: 2025-11-13-59-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-02-20

Test Results


Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Dylan Nault
Date of test: 11/13/2025
Gage No.: 36647
Test No.: 1
Nuclear By: Dylan Nault
Non-Bias Plan No.: 8
Depth: 5"
Material No.: no data
Material Type: Imported Class II Aggregate Base
Impact By: Dylan Nault
Standard Count Density: 1798 g/cc
Count or Density 1: 1675 g/cc
Count or Density 2: 1585 g/cc
Count or Density 3: 1683 g/cc
Standard Count Moisture: 666 g/cc
Moisture Count 1: 59 g/cc
Moisture Count 2: 78 g/cc
Moisture Count 3: 71 g/cc
Sum of Count or Density: 4943 g/cc
Average of Count or Density: 1648 g/cc
Sum of Moisture Count: 208 g/cc
Average of Moisture Count: 69 g/cc
Count Ratio Density: 0.92
Count Ratio Moisture: 0.1
Calculated Percent Relative Compaction: 97 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters): Density Spec 95%

Test was verified on 2/20/2026