Summary for Test 2025-07-07-94-3

Test performed: ASTM D5329-20

Project Information

Project IdentifiersProject ID: 1000681
DEA: 081J7204
EFIS: 0818000099
DIST-CO-RTE-PM08-SBD-40-S0.0/S0.8,0.0/R15.0
Award Date01/17/2025
Closeout Date09/03/2026
Work DescriptionREPLACE AC SURFACING, COLD PLANE AC PAVEMENT, HMA, RSP, AND MGS.
Location DescriptionSAN BERNARDINO COUNTY IN AND NEAR BARSTOW FROM 0.1 MILE WEST OF ROBERTA STREET TO MONTARA ROAD AND FROM ROUTE 15 TO 0.4 MILE EAST OF LAVA WASH BRIDGE
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date07/07/2025 Sample Unique Key94
Date that the sample was received by the laboratory/organization performing the testing07/09/2025 Sample typeVerification
A brief description of the sampleAsphalt Rubber Binder The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byFrancisco
Last name of sampler or witnessed byRUVALCABA Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBlue Diamond-Victorville
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2025-07-07-94
DIME Test ID: 2025-07-07-94-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2026-02-20

Test Results


Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 02/18/2026
Temperature: 25 C
Ball Penetration (P1): 4 mm
Final Dial reading (F1): 66 mm
Ball Penetration (P2): 3 mm
Final Dial reading (F2): 66 mm
Ball Penetration (P3): 3 mm
Final Dial reading (F3): 66 mm
Resilience 1: 38 %
Resilience 2: 37 %
Resilience 3: 37 %
Average Resilience: 37 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2026 ✔