Summary for Test 2025-09-05-105-2

Test performed: AASHTO T30-25

Project Information

Project IdentifiersProject ID: 1001174
DEA: 040X7004
EFIS: 0424000158
DIST-CO-RTE-PM04-SOL-84-3.0/13.6
Award Date06/25/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PAVEMENT AND OVERLAY WITH RHMA-G (BWC).
Location DescriptionSOLANO COUNTY NEAR RIO VISTA FROM 0.4 MILE NORTH OF CACHE SLOUGH FERRY TO YOLO COUNTY LINE
QA Service Level1 (Verified on 08/14/2025)

Sample Information

Sample Taken Date09/05/2025 Sample Unique Key105
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/05/2025
Sample typeQuality Assurance A brief description of the sample3/4 HMA-SP-WMA
The quantity of what the sample constitutes750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byChristian Last name of sampler or witnessed bySousa
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Perkins Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Teichert Perkins
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedHot Bins
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number3 Aggregate Mix Number

Test Details

DIME Sample ID: 2025-09-05-105
DIME Test ID: 2025-09-05-105-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-02-19

Test Results


Individual or cumulative mass retained on each sieve?: Cumulative
Has the fine aggregate sample been reduced?: No
Is an aggregate correction factor used?: No
Was the aggregate obtained using ASTM D8159?: No
Input Type: Calculated
Tester's full name: Henry Concepcion
Date of test: 09/07/2025
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/19/2026