Summary for Test 2025-09-10-128-2

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1001174
DEA: 040X7004
EFIS: 0424000158
DIST-CO-RTE-PM04-SOL-84-3.0/13.6
Award Date06/25/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PAVEMENT AND OVERLAY WITH RHMA-G (BWC).
Location DescriptionSOLANO COUNTY NEAR RIO VISTA FROM 0.4 MILE NORTH OF CACHE SLOUGH FERRY TO YOLO COUNTY LINE
QA Service Level1 (Verified on 08/14/2025)

Sample Information

Sample Taken Date09/10/2025 Sample Unique Key128
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/11/2025
Sample typeQuality Assurance A brief description of the sample3/4"HMA-SP-RAP
The quantity of what the sample constitutes750 Tons From where was the sample collectedJob Site
First name of sampler or witnessed byChristian Last name of sampler or witnessed bySousa
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Perkins Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number8 HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-09-10-128
DIME Test ID: 2025-09-10-128-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-02-18

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Henry Concepcion
Date of test: 09/18/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2276.4 g
Mass Loss: 126.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.36 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.08 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/18/2026