Summary for Test 2026-01-20-45-6
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 1001957 DEA: 021K7204 EFIS: 0224000158 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-273-5.2/14.5 |
| Award Date | 11/21/2028 |
| Closeout Date | Not set |
| Work Description | Brighter 273 Safety - Install lighting |
| Location Description | In Shasta County from 0.1 mile North of Anderson Creek bridge in Anderson to 0.1 North of Buenaventura Boulevard in Redding 6/17/24 JC |
| QA Service Level | 1 (Verified on 02/17/2026) |
Sample Information
| Sample Taken Date | 01/20/2026 | Sample Unique Key | 45 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/21/2026 | Sample type | Preliminary |
| A brief description of the sample | 2 Bags Rock and Soil | The quantity of what the sample constitutes | Structural Section Recommendation |
| From where was the sample collected | Source | First name of sampler or witnessed by | Derek |
| Last name of sampler or witnessed by | Serna | Title of sampler | MREA |
| Telephone number of sampler | Laboratory sample identification | D80133 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | District 2 Lab | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Shoulder Slope near PM 12.0 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-01-20-45
DIME Test ID: 2026-01-20-45-6
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2026-02-18
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 02/04/2026
Minimum soil resistance of the lab measurement: 7700 Ohms
Soil sample temperature: 21.8 C
Soil box constant: 1
pH of soil: 6.94
Minimum soil resistance corrected to 15.5: 8912.75 Ohm-cm
Minimum soil resistivity at 15.5: 8913 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=6.94, p=8913.Ω∙cm
Test was verified on 2/18/2026 ✔