Summary for Test 2026-01-20-45-5
Test performed: ASTM D2487-17Project Information
| Project Identifiers | Project ID: 1001957 DEA: 021K7204 EFIS: 0224000158 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-273-5.2/14.5 |
| Award Date | 11/21/2028 |
| Closeout Date | Not set |
| Work Description | Brighter 273 Safety - Install lighting |
| Location Description | In Shasta County from 0.1 mile North of Anderson Creek bridge in Anderson to 0.1 North of Buenaventura Boulevard in Redding 6/17/24 JC |
| QA Service Level | 1 (Verified on 02/17/2026) |
Sample Information
| Sample Taken Date | 01/20/2026 | Sample Unique Key | 45 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/21/2026 |
| Sample type | Preliminary | A brief description of the sample | 2 Bags Rock and Soil |
| The quantity of what the sample constitutes | Structural Section Recommendation | From where was the sample collected | Source |
| First name of sampler or witnessed by | Derek | Last name of sampler or witnessed by | Serna |
| Title of sampler | MREA | Telephone number of sampler | |
| Laboratory sample identification | D80133 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | District 2 Lab | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Shoulder Slope near PM 12.0 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-01-20-45
DIME Test ID: 2026-01-20-45-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: ASTM D2487-17: Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)
Test Release Date: 2026-02-18
Test Results
Units for Particle Size: millimeters
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 02/18/2026
Percentage of plus 3-in. (75-mm) material: 0 %
Maximum particle size: 25 millimeters
Fines classification: Silty
Percent fines: 37 %
Percent sand: 49 %
Percent gravel: 14 %
Liquid limit: 0
Plasticity Index: 0
Is soil fine-grained or coarse-grained?: coarse-grained
Fine-grained soil classification: no data
Inorganic clay classification: no data
Inorganic silt classification: no data
Organic fine-grained soil classification: no data
Any descriptors added to fine-grained soil classification?: no data
Coarse-grained soil classification: no data
Particle-size diameter at 10% passing (D10): 0.0186 millimeters
Particle-size diameter at 30% passing (D30): 0.058 millimeters
Particle-size diameter at 60% passing (D60): 0.4 millimeters
Gravel classification: no data
Sand classification: silty sand - SM; silty
Any descriptors added to coarse-grained soil classification?: no data
Did field sample contain cobbles or boulders?: no data
Coarse-grained soil dual classification: A silty sand, (SM)
Descriptive information: no data
Coefficient of uniformity (Cu): 21.505
Coefficient of curvature (Cc): 0.452
General comments (publicly viewable) (Max 1000 characters): A silty sand, (SM)
Test was verified on 2/18/2026 ✔