Summary for Test 2026-01-20-45-1
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 1001957 DEA: 021K7204 EFIS: 0224000158 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-273-5.2/14.5 |
| Award Date | 11/21/2028 |
| Closeout Date | Not set |
| Work Description | Brighter 273 Safety - Install lighting |
| Location Description | In Shasta County from 0.1 mile North of Anderson Creek bridge in Anderson to 0.1 North of Buenaventura Boulevard in Redding 6/17/24 JC |
| QA Service Level | 1 (Verified on 02/17/2026) |
Sample Information
| Sample Taken Date | 01/20/2026 | Sample Unique Key | 45 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/21/2026 |
| Sample type | Preliminary | A brief description of the sample | 2 Bags Rock and Soil |
| The quantity of what the sample constitutes | Structural Section Recommendation | From where was the sample collected | Source |
| First name of sampler or witnessed by | Derek | Last name of sampler or witnessed by | Serna |
| Title of sampler | MREA | Telephone number of sampler | |
| Laboratory sample identification | D80133 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | District 2 Lab | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Shoulder Slope near PM 12.0 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-01-20-45
DIME Test ID: 2026-01-20-45-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-02-18
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 02/10/2026
| Sieve Size | Cumulative Mass Retained | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 14478 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 260.0 grams | 98 % | |||||
| 580.0 grams | 96 % | |||||
| 1162.0 grams | 92 % | |||||
| 1438.0 grams | 90 % | |||||
| 2088.0 grams | 86 % | |||||
| 471.4 grams | ||||||
| 31.3 grams | 80 % | |||||
| 71.9 grams | 73 % | |||||
| 116.5 grams | 65 % | |||||
| 158.8 grams | 57 % | |||||
| 214.5 grams | 47 % | |||||
| 269.6 grams | 36.8 % | |||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/18/2026 ✔