Summary for Test 2025-11-13-57-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 995493
DEA: 081G6704
EFIS: 0816000049
DIST-CO-RTE-PM08-RIV-79-5.4/11.4
Award Date05/23/2024
Closeout DateNot set
Work DescriptionHOT MIX ASPHALT, SOIL NAIL, STRUCTURAL CONCRETE AND ROADWAY EXC.
Location DescriptionRIVERSIDE COUNTY NEAR TEMECULA FROM 0.4 MILE SOUTH OF SAGE ROAD TO 1.1 MILES SOUTH OF PAUBA ROAD
QA Service Level1 (Verified on 12/18/2023)

Sample Information

Sample Taken Date11/13/2025 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/13/2025
Sample typeAcceptance A brief description of the sampleNative Subgrade
The quantity of what the sample constitutes22.2 kg From where was the sample collectedJob Site
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byArroyo
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTM 231 TEST LOCATION Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedRte 79 SB, RW 349, Sta 353+50 - 356+62
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2025-11-13-57
DIME Test ID: 2025-11-13-57-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-02-17

Test Results


Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Rigoberto Arroyo
Date of test: 11/13/2025
Gage No.: 86217
Test No.: 1
Nuclear By: Rigoberto Arroyo
Non-Bias Plan No.: 1
Depth: 5"
Material No.: no data
Material Type: Native Backfill
Impact By: Rigoberto Arroyo
Standard Count Density: 2387 g/cc
Count or Density 1: 3254 g/cc
Count or Density 2: 3287 g/cc
Count or Density 3: 2735 g/cc
Standard Count Moisture: 767 g/cc
Moisture Count 1: 147 g/cc
Moisture Count 2: 142 g/cc
Moisture Count 3: 167 g/cc
Sum of Count or Density: 9276 g/cc
Average of Count or Density: 3092 g/cc
Sum of Moisture Count: 456 g/cc
Average of Moisture Count: 152 g/cc
Count Ratio Density: 1.3
Count Ratio Moisture: 0.2
Calculated Percent Relative Compaction: 92.12 %
Reported Percent Relative Compaction: 91 %
General comments (publicly viewable) (Max 1000 characters): Density Spec 95%

Test was verified on 2/17/2026