Summary for Test 2026-02-05-6-7

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/05/2026 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/10/2026
Sample typeQuality Assurance A brief description of the sample2" x 5'-0" F1554 Anchor Bolts
The quantity of what the sample constitutes600 From where was the sample collectedManufacturer
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler8014626352
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUniversal Industrial Sales, Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-015-26 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)1201070558 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt SpecificationF1554 Gr 55
Bolt Length(s)60" Nut Specificationna
Washer Specificationna FinishHDG
Diameter/Size2" Bolt Mfg. Lot Numberna
Rocap Test Requirement(s)na Lubricant Requirements(s)na
Washer Inner Diameter(s)na

Test Details

DIME Sample ID: 2026-02-05-6
DIME Test ID: 2026-02-05-6-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-02-17

Test Results


Number of Bolt Samples: 3
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 02/17/2026
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A1201070558221889000Yield 175000Atlas
21B1201070558221746000Yield 174800Atlas
31C1201070558221771000Yield 174500Atlas

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/17/2026