Summary for Test 2026-01-08-40-2

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1000501
DEA: 081J6104
EFIS: 0818000102
DIST-CO-RTE-PM08-RIV-215-40.5/42.7
Award Date11/05/2024
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location DescriptionRIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date01/08/2026 Sample Unique Key40
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/09/2026
Sample typeQuality Assurance A brief description of the sampleSet 1 Fabricated @ 22:00; Set 2 Fabricated @ 23:25
The quantity of what the sample constitutes2 Sets of 3 - 6X6X21 Rapid Set Concrete Beams From where was the sample collectedJob Site
First name of sampler or witnessed byTQF Last name of sampler or witnessed byInspector
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVanguard Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberHE4X4BM
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Concrete Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-01-08-40
DIME Test ID: 2026-01-08-40-2
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2026-02-13

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: G. Ramirez, D. Nault
Date of test: 01/12/2026
Identification number: #59-2
Width of specimen: 6.0625 inch
Width of specimen 2: 6.0625 inch
Width of specimen 3: 6 inch
Depth of specimen: 6 inch
Depth of specimen 2: 5.9375 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 11346 lb
Maximum load applied 2: 11888 lb
Maximum load applied 3: 12272 lb
Curing history and apparent moisture condition of the specimen: Sand Pit then Water Bath, moist
If specimen was capped, ground or if leather shims were used: Leather Shims
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 4 days
Age of specimen in hours: no data
Modulus of rupture: 980 psi
Modulus of rupture 2: 1050 psi
Modulus of rupture 3: 1050 psi
Modulus of rupture average: 1030 psi
General comments (publicly viewable) (Max 1000 characters): Set #59-2

Test was verified on 2/13/2026