Summary for Test 2026-02-06-7-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994326
DEA: 051C3604
EFIS: 0512000134
DIST-CO-RTE-PM05-SB-217-0.9/1.4
Award Date01/31/2023
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 10/17/2022)

Sample Information

Sample Taken Date02/06/2026 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing02/10/2026
Sample typeQuality Assurance A brief description of the sampleZapScrew Lock couplers for BOX CULVERT PUC #9 verticals being outside of the concrete pour
The quantity of what the sample constitutes4 QA samples From where was the sample collectedJob Site
First name of sampler or witnessed byArman Last name of sampler or witnessed byYazdekhasti
Title of samplerASR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBarSplice Products, Inc Transportation Laboratory (TL) Number0101
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier51-0369
Structure nameGOLETA PUC Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade Steel
Coupler ManufacturerBARSPLICE Intermediate Assembler or Fabricator
Rebar Size#9 Coupler Model09SZBA_A92
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)4000027982 Rebar Heat Number(s)485725
Rebar Size 2 Coupler Unique IDSL-17-03

Test Details

DIME Sample ID: 2026-02-06-7
DIME Test ID: 2026-02-06-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2026-02-13

Test Results


Number of Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 02/13/2026
UTM: NA
Halo ID: NA
Temperature: 0 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
114000027982910.0098912089000service spliceKleinfelder
2240000279829108914089000service spliceKleinfelder
3340000279829109163091500service spliceKleinfelder
4440000279829108893089000service spliceKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/13/2026