Summary for Test 2025-08-04-79-6
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 1000279 DEA: 023H70U4 EFIS: 0223000161 |
|---|---|
| DIST-CO-RTE-PM | 02-TRI-299-15.0/25.7 |
| Award Date | 08/09/2024 |
| Closeout Date | Not set |
| Work Description | RHMA-G, HMA (TYPE A), COLD PLANE AC, & SOLDIER PILE RETAINING WALL. |
| Location Description | TRINITY COUNTY NEAR DEL LOMA FROM 1.0 MILE EAST OF TRINITY RIVER BRIDGE NO.05-0006 TO 0.1 MILE WEST OF PRAIRIE CREEK ROAD |
| QA Service Level | 1 (Verified on 04/30/2024) |
Sample Information
| Sample Taken Date | 08/04/2025 | Sample Unique Key | 79 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/04/2025 |
| Sample type | Production Start-Up | A brief description of the sample | 16 boxes of Lime Treated 1/2-inch RHMA-G (PG 64-16 CR) |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | D79984 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | J.F. Shea Construction — Fawndale Rock and Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 036705 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | 3908125 |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 7.5 | Virgin binder PG | PG 64-16 |
| Design binder PG | Binder Supplier | Valero (Benicia, CA) | |
| RAP content (%) | 0 | WMA Additives | No |
| Antistrip type | Lime |
Test Details
DIME Sample ID: 2025-08-04-79
DIME Test ID: 2025-08-04-79-6
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2026-02-12
Test Results
Specified number of passes at 12.7 mm: 15000
Specimen Preparation Method: PMLC
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 08/19/2025
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: 7.8 %
Air Void Content for specimen A-2: 8.2 %
Air Void Content for specimen B-1: 8.1 %
Air Void Content for specimen B-2: 7.9 %
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 1.43 mm
Maximum impression at 5000 passes (right wheel): 1.23 mm
Average impression at 5000 passes (left/right avg): 1.33 mm
Maximum impression at 10000 passes (left wheel): 1.7 mm
Maximum impression at 10000 passes (right wheel): 1.5 mm
Average impression at 10000 passes (left/right avg): 1.6 mm
Maximum impression at 15000 passes (left wheel): 1.93 mm
Maximum impression at 15000 passes (right wheel): 1.74 mm
Average impression at 15000 passes (left/right avg): 1.84 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters): Rut=0.1in.@N₁₅₀₀₀,
Nf>15000,
SIP>15000
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| D79984, 036705, 02-3H70U3, HWT | 1034.70 KB | 02/12/2026 | 2025-08-04-79-6 | Info |
Test was verified on 2/12/2026 ✔
