Summary for Test 2025-12-08-59-1
Test performed: CTM 524-March 2013Project Information
| Project Identifiers | Project ID: 1000501 DEA: 081J6104 EFIS: 0818000102 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-215-40.5/42.7 |
| Award Date | 11/05/2024 |
| Closeout Date | Not set |
| Work Description | INDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE. |
| Location Description | RIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING |
| QA Service Level | 1 (Verified on 09/02/2024) |
Sample Information
| Sample Taken Date | 12/08/2025 | Sample Unique Key | 59 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/09/2025 |
| Sample type | Quality Assurance | A brief description of the sample | Set 1 Fabricated @ 21:03; Set 2 Fabricated @ 23:52 |
| The quantity of what the sample constitutes | 2 Sets of 3 - 6X6X21 Rapid Set Concrete Beams | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | TQF | Last name of sampler or witnessed by | Inspector |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vanguard | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | HE4X4BM |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Back of Concrete Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-12-08-59
DIME Test ID: 2025-12-08-59-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2026-02-11
Test Results
Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: R. Jarquin, D. Nault
Date of test: 12/12/2025
Identification number: #48-1
Width of specimen: 6.125 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6.0625 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.125 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 11177 lb
Maximum load applied 2: 12068 lb
Maximum load applied 3: 10555 lb
Curing history and apparent moisture condition of the specimen: Sand Pit then Water Bath, moist
If specimen was capped, ground or if leather shims were used: Leather Shims
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 4 days
Age of specimen in hours: no data
Modulus of rupture: 940 psi
Modulus of rupture 2: 1010 psi
Modulus of rupture 3: 900 psi
Modulus of rupture average: 950 psi
General comments (publicly viewable) (Max 1000 characters): Set #48-1
Test was verified on 2/11/2026 ✔